Description:
-Product name: Outdoor Gas stove
-Material: stainless steel, Copper
-Power: 16000W
-Unfold size: φ195*120mm Folden size:φ150*110mm,hose length: 60cm
-Net weight: 620G
-Max bearing: 15 KGS(33LBS)
-Suit for diameter: above 9cm cookware
-Packing: Gas stove*1, Adapter*1,Storage bag*1
Common faults and troubleshooting methods:
The normal flame of a card furnace is light blue, with a clear flame inside,
a height of about 60 meters, slight noise, and strong firepower. If there is
a small flame. The reasons and elimination methods are as follows:
1) The burner cover and fire hole are blocked by dirt, hindering the
flow of mixed gas from the burner. Clean the dirt from the fire hole.
2) The nozzle is blocked, unscrew the nozzle and clean it thoroughly.
3) The inlet and nozzle of the regulator are blocked by rust, which hinders
the flow of gas from the cylinder. Replace regulator with a qualified one.
4The copper tube is flattened and the ventilation is blocked. Straighten the copper tube or replace it.
5) In addition, attention should be paid to reasons such as the gas being used up and valves not being fully opened, and corresponding measures can be taken to solve them.
Is it normal for a card furnace to have a red fire?
Why does a card furnace have a booming fire?
The main reasons for the hot fire of the card furnace are as follows:
1) Gas reason: When there is too much moisture or impurities in the combustion gas, it will cause the flame color to appear red.
2) Reason for dust: When there is dust in the house or when cooking, the amount of water and oil in the air increases, which can also easily lead to a red fire.
3) Reason for air door: This situation may also occur when the air door is not adjusted properly.
What should I do when I encounter a card furnace that keeps failing to ignite?
If the gas stove fails to ignite continuously, the following procedure should be followed for inspection:
Firstly, check if the air source switch is in the on state. If it is in the on state, then secondly, check if the connecting copper pipe is flattened or bent. If it is not flattened or bent, then finally, pick up the pot holder and check if there is any ignition at the ignition nozzle:
1) If there is no ignition, check if the discharge needle discharges
a、 If the discharge needle does not discharge, it indicates that the discharge needle is faulty and should be replaced.
b、 If the discharge needle discharges, it indicates that there is a partial blockage in the air circuit or a valve body failure, and it should be replaced.
2) If it ignites: a. If it can burn normally, it indicates that the igniter position is too high, and the user should be guided to gently ignite the igniter
Press down a few times and place the pot rack on top. b、 If there is a fire, but the flame is too weak to reach the furnace, it is
If the gas pressure is too low, it may be due to the gas cylinder being almost used up or the regulating valve malfunctioning. If it ignites and reaches the fire cover, but still does not ignite, it indicates that the valve body is blocked. Guide the user to use fine wire to clear the spray.